Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Optom Vis Sci ; 99(11): 800-806, 2022 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-36301598

RESUMO

SIGNIFICANCE: Scleral lenses rely on the scleroconjunctival region without bearing the cornea, which could improve the symptoms and modify the corneal nerve plexus morphology. PURPOSE: This study aimed to evaluate symptoms and changes in corneal nerve plexus morphology and density of Langerhans cells in keratoconus patients with and without intrastromal corneal ring before and after scleral lens wear. METHODS: Sixteen scleral lens wearers with keratoconus were recruited for this short-term experimental pilot study. Subjects were divided into two groups: keratoconus group and intrastromal corneal ring segment group. All subjects were examined in two visits: baseline (before scleral lens wear) and after 6 months of scleral lens wear, after lens removal. The Schirmer I test, the Ocular Surface Disease Index, tear breakup time, and in vivo confocal microscopy were evaluated. RESULTS: The mean age was 42.33 ± 11.27 years. A significant decrease in tear breakup time was found in the total group ( P = .01, Wilcoxon) compared with baseline. Ocular Surface Disease Index score had decreased after 6 months of scleral lens wear in the keratoconus with intrastromal corneal ring segment subgroup ( P = .03, Wilcoxon) and in the total group ( P = .001, Wilcoxon). No statistical changes in nerve density, tortuosity, and ramification were found for either the total group or the subgroup. However, the mean nerve length was higher in all groups, especially in the keratoconus subgroup ( P = .03, Wilcoxon) after 6 months of scleral lens wear. Regarding optical density, the total group showed a significant increase after 6 months of wearing ( P = .02, Wilcoxon). Finally, Langerhans cell density was not statistically different in any group. CONCLUSIONS: These results suggest that scleral lens wearing improves the symptoms and increased the mean length nerves after 6 months of wear use in keratoconus patients.


Assuntos
Lentes de Contato , Ceratocone , Humanos , Adulto , Pessoa de Meia-Idade , Ceratocone/diagnóstico , Ceratocone/terapia , Ceratocone/etiologia , Projetos Piloto , Lentes de Contato/efeitos adversos , Córnea , Esclera
2.
Optom Vis Sci ; 97(9): 726-731, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32941332

RESUMO

SIGNIFICANCE: Scleral lenses (SLs) rest on the scleroconjunctival region, which could result in a mechanical impact in the bulbar conjunctiva that can hypothetically modify some properties of conjunctival cells. PURPOSE: The purpose of this study was to evaluate the differences in goblet cell density (GCD) and mucin cloud amplitude (MCA) between superior and inferior bulbar conjunctiva in SL wearers. METHODS: A total of 26 eyes wearing SL were randomly selected from 26 subjects (11 females) with different grades of keratoconus enrolled in a prospective clinical series. Superior and inferior conjunctival impression cytologies were performed and therefore analyzed with scanning laser confocal microscopy to evaluate GCD and MCA. All subjects filled out the Ocular Surface Disease Index (OSDI) questionnaire. RESULTS: The mean ± standard deviation OSDI score was 23.62 ± 15.12. Although a higher density of goblet cells was observed in the samples taken in the superior conjunctiva (74.70 ± 57.55 cells/mm) than on the inferior conjunctiva (55.91 ± 34.80 cells/mm), there were no statistically significant differences between them (P = .14, Wilcoxon). Regarding MCA, no differences were found between superior (21.81 ± 3.30 µm) and inferior (20.72 ± 2.95 µm) samples (P = .201, Wilcoxon). No statistically significant differences were found in GCD and MCA regarding the time of SL wear. CONCLUSIONS: There were no differences in GCD and MCA in the samples taken in the superior and inferior conjunctival areas. Also, it seems that the SL wearing time does not affect the density and secretion of goblet cells. Prospective studies need to be conducted in larger samples to confirm those outcomes.


Assuntos
Túnica Conjuntiva/citologia , Lentes de Contato , Células Caliciformes/citologia , Ceratocone/terapia , Esclera , Adulto , Contagem de Células , Feminino , Humanos , Masculino , Microscopia Confocal , Pessoa de Meia-Idade , Mucinas/metabolismo , Projetos Piloto , Estudos Prospectivos , Ajuste de Prótese , Microscopia com Lâmpada de Fenda , Lágrimas/metabolismo , Adulto Jovem
3.
Eye Contact Lens ; 45(2): 141-148, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30005055

RESUMO

OBJECTIVE: To evaluate changes in the anterior corneal curvature and aberrometry after scleral contact lens wear in keratoconus (KC) subjects with and without intracorneal ring segments (ICRS). METHODS: Twenty-six subjects diagnosed with keratoconus were selected to participate in the study. Subjects were divided into 2 groups, those with ICRS (KC-ICRS group) and those without ICRS (KC group). Subjects were instructed to wear 16.5-mm scleral lenses for 8 hours. Topographic and aberrometric parameters were evaluated before lens wear and immediately after lens removal. Anterior corneal curvature was evaluated at corneal diameters of 2, 4, 6, and 8 mm, and corneal aberrations were measured at 4-, 6-, and 8-mm pupil diameters. RESULTS: The mean age of subjects was 36.95±8.95 years. In KC group, there was a statistically significant flattening of the central corneal curvature, from 6.98 to 7.09 mm (P<0.05). No changes were found in the central corneal curvature in the KC-ICRS group. The KC group showed anterior corneal curvature flattening, mainly in the nasal quadrant. The KC-ICRS group showed flattening primarily in the inferior hemisphere. In the KC group, spherical aberration for 6-mm pupil increased significantly. In the KC-ICRS group, changes in aberrations were significant for high-order root mean square at 4- and 6-mm pupil diameters (P<0.05), for oblique astigmatism for 4 mm and 6 mm, and for vertical coma for 4-mm pupil (P<0.05). CONCLUSION: Short-term scleral lens wear showed flattening of the anterior corneal surface in all subjects. In the KC group, the flattening was more pronounced in the nasal quadrant while changes were more pronounced inferiorly in KC-ICRS group.


Assuntos
Lentes de Contato de Uso Prolongado , Córnea/patologia , Topografia da Córnea/métodos , Ceratocone/terapia , Acuidade Visual , Adulto , Feminino , Seguimentos , Humanos , Ceratocone/diagnóstico , Ceratocone/fisiopatologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Esclera , Fatores de Tempo , Tomografia de Coerência Óptica
4.
Clin Exp Optom ; 100(6): 577-582, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28125853

RESUMO

BACKGROUND: The aim was to evaluate the turbidity and thickness of the post-lens tear layer and its effect on visual quality in patients with keratoconus after the beginning of lens wear and before lens removal at the end of eight hours. METHODS: Twenty-six patients with keratoconus (aged 36.95 ± 8.95 years) participated voluntarily in the study. The sample was divided into two groups: patients with intrastromal corneal ring (ICRS group) and patients without ICRS (KC group). Distance visual acuity (VA), contrast sensitivity, pachymetry, post-lens tear layer height and post-lens tear layer turbidity (percentage area occupied and number of particles per mm2 ) were evaluated with optical coherence tomography before and after wearing a scleral lens. RESULTS: A significant increase of turbidity was found in all groups assessed (p < 0.05). The number of particles per square millimetre was eight times higher after scleral lens wear than at the beginning of wearing the lens for all groups. VA decreases in all groups after scleral lens wear (p < 0.001). All patients showed a statistical diminishing of contrast sensitivity after scleral lens wear (p < 0.05). A significant correlation was found for both turbidity parameters with distance VA but no correlation between turbidity and post-lens tear layer thickness at the beginning was found (p > 0.05). A strong correlation in all groups between the post-lens tear layer at the beginning and differences of tear layer thickness between two measures was also found (p < 0.05). CONCLUSION: The VA decrease during the scleral lens wearing, filled with preserved saline solution, was due to the increasing post-lens tear layer turbidity.


Assuntos
Lentes de Contato , Ceratocone/terapia , Esclera , Lágrimas/metabolismo , Acuidade Visual/fisiologia , Adulto , Sensibilidades de Contraste/fisiologia , Paquimetria Corneana , Feminino , Humanos , Ceratocone/metabolismo , Ceratocone/fisiopatologia , Masculino , Pessoa de Meia-Idade , Nefelometria e Turbidimetria , Fatores de Tempo , Tomografia de Coerência Óptica
5.
Eye Contact Lens ; 43(6): 346-351, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27203795

RESUMO

OBJECTIVE: To evaluate the ocular surface temperature using an infrared thermography camera before and after wearing scleral lens in patients with keratoconus and correlate these results with the tear production and stability. METHODS: A pilot, experimental, short-term study has been performed. Twenty-six patients with keratoconus (36.95±8.95 years) participated voluntarily in the study. The sample was divided into two groups: patients with intrastromal corneal ring (KC-ICRS group) and patients without ICRS (KC group). Schirmer test, tear breakup time (TBUT), and ocular surface temperature in the conjunctiva, limbus, and cornea were evaluated before and after wearing a scleral lens. RESULTS: The patients wore the scleral lenses from 6 to 9 hours with average of 7.59±0.73 hours. No significant changes in Schirmer test and TBUT were found for both groups. No temperature differences were found between the KC-ICRS and the KC groups for all zones evaluated. There was a slight, but statistically significant, increase in the inferior cornea, temporal limbus, and nasal conjunctival temperature for KC-ICRS group and temporal limbus temperature decreasing for the KC group after wearing scleral lens (P<0.05). The conjunctiva and limbus temperature was statistically higher than the central cornea for both groups before and after scleral lenses wearing (P<0.05), but no difference in the peripheral cornea was found. No statistically significant differences in the central corneal temperature were found between the groups after scleral lens wearing (P>0.05). CONCLUSION: Scleral contact lens seems not to modify the ocular surface temperature despite the presence of the tear film stagnation under the lens.


Assuntos
Temperatura Corporal/fisiologia , Túnica Conjuntiva/fisiologia , Lentes de Contato , Córnea/fisiologia , Ceratocone/terapia , Próteses e Implantes , Esclera , Adulto , Feminino , Humanos , Ceratocone/metabolismo , Limbo da Córnea/fisiologia , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos , Lágrimas/metabolismo , Termografia/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...